Seitenansicht 88
User Manual
87
Enable Alarm Output
Select the item to enable alarm relay output.
Send Alarm Message by FTP/E-Mail
The Administrator can select whether to send an alarm message by
FTP and/or E-Mail when an alarm is triggered.
Upload Image by FTP
Select this item and the Administrator can assign a FTP site and
configure various parameters as shown in the figure below. When the
alarm is triggered, event images will be uploaded to the appointed FTP
site.
<Pre-trigger buffer> function allows users to check what happened to
cause the trigger. The <Pre-trigger buffer> frame rate could be
pre-determined.
On the other hand, <Post-trigger buffer> is for users to upload certain
amount of images after the alarm input is triggered.
Check the box <Continue image upload> to upload the triggered
images during certain time or keep uploading until the trigger is off.
Select <Upload for __sec> and enter the duration in the blank. The
images of the duration will be uploaded to FTP when the alarm input is
triggered. The setting range is from 1 to 9999 seconds. Select <Upload
during the trigger active> to make the images keep being uploaded to
FTP during the trigger active until the alarm is released. Set the Image
frequency as the upload frame rate. The setting range is from 1 frame
to 15 frames.
NOTE: Make sure FTP configuration has been completed.
Refer to FTP for further details.