Black BLK-SY10 Series Bedienungsanleitung Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 42
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN
9
F7
S
eries 3-Wa
y,
HDU Butter
y
Valve
Resilient Seat
,
304 Stainless Dis
c
Technical Data
S
ervic
e
chilled, hot water, 60% gl
y
col
Flow characteri
s
ti
c
modifi ed linea
r
Controllable fl ow ran
g
e 82°
S
ize
s
2” t
o
12”
T
ype of end fi tting for use with AN
S
I 125/150 fl anges
M
aterial
s
B
ody
Body fi nish
Di
sc
S
ea
t
S
haft
O
-rin
g
B
ushings
ductile iron ASTM A536
epoxy powder fi nish
30
4
s
t
a
inl
ess
s
t
eel
EPDM
s
tandard
416
s
ta
i
n
l
e
ss
s
tee
l
EPDM
R
PTFE
M
edia temperature ran
g
e -22°F to 250°F [-30°C to 120°C]
B
ody pressure ratin
g
ASME/ANSI Class 12
5
Close-off
p
ressur
e
50
p
si
R
angeabilit
y
10:1 (
f
or 30° to 70° range)
M
aximum velocit
y
12 FPS
Leaka
ge
bubble ti
g
ht
50 psi bubble tight shut-off
Long stem design allows for
2
” insulation
Valve face-to-face dimensions compl
y
with API 609 & MSS-SP-67
• Completel
y
assembled and tested, read
y
for installation
• Tees compl
y
with ASME/ANSI B16.1 Class 125 fl ange
s
Applicatio
n
These valves are designed to meet the needs of HVAC and commercial
applications requiring bubble tight shut o
ff
f
or liquids. T
y
pical applications
include chiller isolation, cooling tower isolation, change-over systems, large
air handler coil control, bypass and process control applications. The large
C
v
values provide
f
or an economical control valve solution
f
or larger
ow
applications. Designed
f
or use in Victaulic piping systems when mated to
V
ictaulic 41 series
ange nipples.
Jobsite Not
e
V
alves should be stored in a weather protected area prior to construction.
C
omplete installation recommendations can be found in Belimo’s Installation
and Maintenance Instructions
f
or F7…HDU Butter
y Valves.
N
ominal
S
ize T
y
pe
S
uitable Actuators
C
v
90°
C
v
60°
IN
DN
[mm]
3-way
Spring
Non-Spring
Electronic
Fail-Safe
1
15
4
4 2
5
0
F750HD
U
AF
Series
AM
SY Series
1
96 7
5
2½”
65
F765HDU
30
2 11
6
3”
80
F780HD
U
GM Series
6
00 230
4”
1
00
F
7100HD
U
GK
Series
1
022 392 5
1
25
F
7125HD
U
1
579 605
6”
1
50
F
7150HD
U
3
1
36
12
0
2
8”
2
00
F
7200HD
U
5
340
204
7
10”
2
5
0
F
7
2
5
0HDU
82
5
0
3062
12”
300
F
7
300HDU
M
O
D
O
N
/O
FF
Valve Size
C
v
10°
2
3
4
50°
6
70° 80
°
90°
F750HDU
2”
115 .06
3
7
15
2
7
4
4
7
0
105
1
15
F765HD
U
2
½” 196 .1
0
6
1
2
25
45
75 119 17
8
1
96
F780HD
U
3
302 .2
0
9
1
8
3
9 7
0
116 183 275 302
F7100HD
U
4
6
00 .3
0
1
736
7
8 139 230 364 54
6
600
F7125HDU 5
1022 .5
0
29 6
1
1
33 237 392 620 93
0
1022
F7150HDU 6
1579 .8
0
45
9
5
2
05 366 605 958 143
7
1579
F7200HD
U
8
3136
2
89 188
4
08 727 1202 1903 285
4
3136
F7250HD
U
10”
5
340
3
1
51 320
6
94 1237 2047
3
240 4859 5340
F7300HD
U
12” 8250 4
2
34
4
95
1
072 191
1
3062 5005 750
7
8250
O
50904 - 02/12 -
S
ubject to change.
©